Local control unit of the SAOL system
Electronic multifunction alarm siren
Compact two-horn siren for smaller areas: housing estates, industrial sites and zones around facilities. Alarm signals and voice messages, more than 10 days on battery power.

| Frequency response | 200–10 000 Hz |
|---|---|
| Alarm frequency | dual-tone 415/425 Hz |
| Sound level – directional horns (1 row, 0°) | 109 dB(A) / 30 m |
| Sound level – back-to-back horns (1 row, 180°) | 103 dB(A) / 30 m |
| Number of horns | 2 |
| Number of amplifiers | 1 (dual) |
| Amplifier power | 300 W |
| Maintenance-free batteries | 2 × 12 V 24 Ah |
| Mains supply | AC 230 V 50 Hz |
| Standby power consumption | avg. 6 W |
| Power consumption while charging | max 100 W |
| Standby without mains power | > 10 days |
| Alarms within 48 h | > 15 alarms × 1 min (20 °C) |
| Communication | RS-485 (RJ45) |
| Horn array dimensions (W × H × D) | 840 × 950 × 160 mm |
| Horn array material | aluminium alloy |
| Horn array weight | 19 kg |
| Horn array operating temperature | −50…+70 °C |
| Control cabinet dimensions | 600 × 600 × 210 mm |
| Cabinet weight incl. batteries | 68 kg |
| Cabinet operating temperature | −25…+70 °C |
| Environment | Range to threshold |
|---|---|
| Open terrain | ≈ 1 km |
| Small towns | ≈ 950 m |
| Housing estates | ≈ 710 m |
| Large cities | ≈ 550 m |
Estimate based on manufacturer curves: 103 dB(A) at 30 m (back-to-back horns), 6 dB loss per doubling of distance plus attenuation depending on the built environment. Actual range depends on terrain, mounting height and background noise — we run an acoustic simulation for each site.
Planning a warning system?
Let’s talkSiren and control selection, design and a quote — including for public tenders.